KB-30663: Elipse E3 running in Windows Server 2008.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30663: Elipse E3 running in Windows Server 2008.

Question: Does Elipse E3 work in Windows Server 2008? Solution: Yes; after E3 v. 3.2, all versions/builds work normally with Windows Server 2008.

Read More

KB-30665: Working with functions in E3 scripts.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30665: Working with functions in E3 scripts.

Question: How can I work with a function in E3 scripts? Solution: To do so, you must set the function with the structure: Function Name(parameter1, parameter2,.., parameterN) scriptEnd function Example: Sub…

Read More

KB-30670: Printing a report via application.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-30670: Printing a report via application.

Question: Can I print a report via Elipse SCADA? Solution: Yes. To do so, access the Organizer, and set up the printer in the Reports–Printers folder. Then, just write a…

Read More

KB-30529: Error 80004005 when accessing Access database.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30529: Error 80004005 when accessing Access database.

Question: When testing the connection to an Access database, the error 80004005 is displayed. How can I fix this? Solution: To do so, check if the *.mdb file path is…

Read More

KB-30556: Script error with Overflow message.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30556: Script error with Overflow message.

Question: On Windows 2003 Server SP2, when executing scripts that work with Double data, a script error occurs with an Overflow message. How can I fix the problem?Solution: To do…

Read More

KB-38865: Reconectando o Viewer a outro E3 Server via script.

25 de March de 201921 de February de 2024Elipse SoftwareLeave a Comment on KB-38865: Reconectando o Viewer a outro E3 Server via script.

Descrição: É possível reconectar o Viewer a outro E3Server através de um script? Solução: Sim, é possível. Para isso, deve-se escrever um script. No exemplo abaixo, o script é executado…

Read More

KB-38865: Reconnecting the Viewer to another E3 Server via scripts.

25 de March de 201921 de February de 2024Elipse SoftwareLeave a Comment on KB-38865: Reconnecting the Viewer to another E3 Server via scripts.

Question: Can I automatically reconnect the Viewer to another E3Server via scripts? Solution: Yes, you can. To do so, you must write a script. In the example below, the script…

Read More

KB-30359: Exporting a report to PDF.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-30359: Exporting a report to PDF.

Question: How can I export a report to PDF format? Solution: To do so, you must first download a PDF printer (PDFCreator, for example) and set it as Windows’s default…

Read More

KB-38730: Acessando elementos de um Tag Bloco via VBScript.

25 de March de 201924 de November de 2022Elipse SoftwareLeave a Comment on KB-38730: Acessando elementos de um Tag Bloco via VBScript.

Descrição: Em uma comunicação com o driver VBScript, como acessar elementos de um Tag Bloco através do script do driver? Solução: Para acessar os elementos do bloco, deve-se utilizar um…

Read More

KB-30431: Options on the Historic’ Analysis window disabled for users that are not Windows Administrators.

25 de March de 20192 de April de 2020Elipse SoftwareLeave a Comment on KB-30431: Options on the Historic’ Analysis window disabled for users that are not Windows Administrators.

Question: When I execute a script with HistoricName.Analysis() as an administrator logged into Windows XP, it works properly. However, when another type pf user logs in, the options on the…

Read More