KB-39044: Registrando usuário logado na aplicação em um arquivo texto.

25 de March de 20196 de June de 2019Elipse SoftwareLeave a Comment on KB-39044: Registrando usuário logado na aplicação em um arquivo texto.

Descrição: Como registrar o usuário logado no Elipse SCADA em um arquivo texto (*.txt)? Solução: Para isso, basta escrever o atributo userName da aplicação, via função WriteToFile, no arquivo texto…

Read More

KB-30896: Blocking users after N number of failed logins.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30896: Blocking users after N number of failed logins.

Question: How can set up the E3 application to block users after n failed attempts to log in? Solution: To do so, right-click the E3Admin and select Domain–Options. Then, access…

Read More

KB-30890: Changing the messages zone via Demo Tag.

25 de March de 201917 de January de 2020Elipse SoftwareLeave a Comment on KB-30890: Changing the messages zone via Demo Tag.

Autor
Mateus Machado

Read More

KB-39027: Conectando a hardkey após editar a aplicação em modo DEMO.

25 de March de 201911 de July de 2019Elipse SoftwareLeave a Comment on KB-39027: Conectando a hardkey após editar a aplicação em modo DEMO.

Descrição: Após editar a aplicação em modo DEMO no Elipse SCADA, é possível conectar a hardkey para salvar as mudanças? Solução: Não, não é possível. Após abrir o Elipse SCADA…

Read More

KB-30714: Limiting the number of Viewers per computer.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30714: Limiting the number of Viewers per computer.

Question: How can I limit the number of Viewers per computer to no more than one? Solution: To do so, you can create a Viewers Group for each computer, and…

Read More

KB-30772: Acknowledging alarms in two Domains at the same time.

25 de March de 20199 de September de 2022Elipse SoftwareLeave a Comment on KB-30772: Acknowledging alarms in two Domains at the same time.

Question: There are two machines, each one executing an E3 Server, which communicate to a single PLC. Can I configure the application to acknowledge alarms in both Domains when acknowledging…

Read More

KB-30796: Issuing commands from the WebViewer.

25 de March de 201922 de January de 2020Elipse SoftwareLeave a Comment on KB-30796: Issuing commands from the WebViewer.

Question: Can I send commands to the E3Server via WebViewer? Solution: Yes. However, you must remember that the WebViewer uses a Viewer license to work, so the hardkey of the…

Read More

KB-30877: OPC communication only works via Studio.

25 de March de 201927 de May de 2019Elipse SoftwareLeave a Comment on KB-30877: OPC communication only works via Studio.

Question: When E3 is an OPC Client and communication happens via E3 Studio, it works properly. However, when executing the Domain, it does not work. Why does this occur? Solution:…

Read More

KB-30692: Changing a Demo Tag’s variation.

25 de March de 201917 de January de 2020Elipse SoftwareLeave a Comment on KB-30692: Changing a Demo Tag’s variation.

Question: How can I enable/disable a Demo Tag’s variation? Solution: To do so, you must edit the tag’s Enabled property: Enabled = True (the tag varies) Enabled = False (the…

Read More

KB-30715: Negative values not being read properly

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-30715: Negative values not being read properly

Question: Why are the negative values not being read properly? Solution: To fix the problem, you must change the Modbus function’s Datatype to Int (16 or 32). To do so,…

Read More