Category: AlarmServer / AlarmConfig

KB-108744: Returning Elipse E3’s active alarms via database.

14 de July de 2020Marco Antonio Gomes SilvaLeave a Comment on KB-108744: Returning Elipse E3’s active alarms via database.

Question: How can I return the active alarms in Elipse E3 via database records? Solution: In order to return the active alarms  in Elipse E3 (acknowledged or not), you must…

Read More

KB-108454: Changing sub-conditions messages in a discrete alarm at runtime.

7 de May de 2020Délio DaminLeave a Comment on KB-108454: Changing sub-conditions messages in a discrete alarm at runtime.

Question: How can I change, at runtime, the sub-conditions messages (in and out) of a discrete alarm inside an Elipse E3‘s XObject? For example, can I add the Name property…

Read More

Recording alarms in different databases and tables.

25 de March de 201929 de May de 2019Enrico Busnello AmorimLeave a Comment on Recording alarms in different databases and tables.

Question: Can I create multiple alarm servers in an E3 application? If not possible, can two alarms be saved in two databases at the same time via Alarm Server? Solution:…

Read More

Double acknowledgement in Elipse E3’s alarms.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on Double acknowledgement in Elipse E3’s alarms.

Question: What are the benefits of enabling double acknowledgement (DobleAckRequired property = True) at Elipse E3’s alarms? Solution: When an alarm has been set up with double acknowledgement in E3,…

Read More

Default Link in Alarms Messages.

25 de March de 20195 de July de 2019Elipse SoftwareLeave a Comment on Default Link in Alarms Messages.

Whenever similar alarms are set up in different objects in Elipse Power, each alarm’s messages must be edited individually. This can be rather inconvenient, especially when there are a large number of alarms in the application.
Autor
Mateus Machado

Read More

KB-51116: Error 80004005 when acknowledging alarm at runtime.

25 de March de 201911 de September de 2019Elipse SoftwareLeave a Comment on KB-51116: Error 80004005 when acknowledging alarm at runtime.

Question: When a certain alarm is acknowledged, the following error message is displayed: Why does this happen? How can I work around this? Solution: There are quite a few causes…

Read More

KB-32344: Setting up a delay time to activate a digital alarm.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-32344: Setting up a delay time to activate a digital alarm.

Question: How can I set up a delay time to activate a digital alarm? Solution: To do so, right-click the alarm in E3Studio and select the option Properties. On Digital…

Read More

KB-31777: Setting up a bit’s variation as an event.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-31777: Setting up a bit’s variation as an event.

Question: How can I set up a bit’s change in status as an event, and not as an alarm? Solution: To do so, set it up normally as an alarm…

Read More

KB-28435: Activating a digital alarm according to values in two tags.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28435: Activating a digital alarm according to values in two tags.

Question: How can a digital alarm be set up to be activated when the values of two different tags are both TRUE? Solution: To do so, just write an AND…

Read More

KB-35679: Acknowledging alarms via Viewer Only.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-35679: Acknowledging alarms via Viewer Only.

Question: Can alarms be acknowledged via Viewer Only? Solution: No, this is not possible. A Viewer Only does not allow sending commands to the server, and the Alarm Server, which…

Read More