KB-28701: Simulating analog values.

25 de March de 201920 de January de 2020Elipse SoftwareLeave a Comment on KB-28701: Simulating analog values.

Question: How can I simulate analog values in the IEC Driver slave’s I/O Tags to be read in the IEC master? Solution: To do so, create a demo tag in…

Read More

KB-28793: Communication with Moeller’s XC-201 PLC .

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28793: Communication with Moeller’s XC-201 PLC .

Question: Which drivers communicate with Moeller’s CPU XC-201? Solution: There is no driver to communicate with this PLC. CPU XC-201 is an OPC Server, so the communication happens via OPC.

Read More

KB-28868: Setting up the Viewer to work with four monitors.

25 de March de 201924 de November de 2022Elipse SoftwareLeave a Comment on KB-28868: Setting up the Viewer to work with four monitors.

Question: How can I set the Viewer’s resolution to be used with four monitors in 2×2 format, each monitor with 2560 x 1600? Solution: To do so, you must sum…

Read More

KB-28512: Setting up an alarm and displaying it on screen.

25 de March de 201928 de July de 2023Elipse SoftwareLeave a Comment on KB-28512: Setting up an alarm and displaying it on screen.

Question: How can I set an alarm and display the active ones on screen? Solution: To do so, open the Organizer, select the tag to be supervised, and configure the…

Read More

KB-28527: Information exchange via OPC between Elipse E3 servers.

25 de March de 201918 de August de 2020Elipse SoftwareLeave a Comment on KB-28527: Information exchange via OPC between Elipse E3 servers.

Question: Can I use OPC communication in order to exchange information between two Elipse E3 applications? Solution: One thing should be taken into consideration when planning information exchange between Elipse…

Read More

KB-28571: SCADA full screen closed with Ctrl+F4.

25 de March de 20199 de September de 2019Elipse SoftwareLeave a Comment on KB-28571: SCADA full screen closed with Ctrl+F4.

Question: Why is a SCADA full screen being closed when pressing Ctrl+F4? Solution: This is SCADA’s standard behavior. To change it, you can use the Ctrl+F4 combination in an OnKeyPress()…

Read More

KB-28574: UserAdministration() function only executed by users with permission.

25 de March de 20194 de August de 2025Elipse SoftwareLeave a Comment on KB-28574: UserAdministration() function only executed by users with permission.

Question: There is a script in the application using UserAdministration() function, but when the function is executed nothing happens. Why is this happening? Solution: This function is only executed if…

Read More

KB-28541: Communicating with Siemens S7-200 CP243 via Ethernet.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-28541: Communicating with Siemens S7-200 CP243 via Ethernet.

Question: Can MProt driver communicate with S7-200 CP243 via Ethernet? Solution: Yes, it can. To do so, just check the ISOTCP243 option in the Network field, and configure the Ethernet…

Read More

KB-28530: IOKit: the basics.

25 de March de 201924 de April de 2019Jerônimo Mulinari NetoLeave a Comment on KB-28530: IOKit: the basics.

Question: What is the IOKit? Solution: The IOKit is a shared component used by Elipse’s I/O drivers that implements the default access to its physical level and provides interfaces to:…

Read More

KB-28535: Sharing directories for Remote Domains.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28535: Sharing directories for Remote Domains.

Question: In the Domain File, why do I need to inform the shared directory where application to be accessed is? Solution: You must do this so that E3 will access…

Read More