OPC DA client communication won’t work due to authentication failure.

7 de May de 2020Marco Antonio Gomes SilvaLeave a Comment on OPC DA client communication won’t work due to authentication failure.

Question: What could have caused a communication failure via Elipse E3‘s OPC DA client? I suspect the server isn’t accepting the client’s authentication. In this example, I’m using GE’s B&R.DviOPC.2…

Read More

Configuring the OPC UA Driver.

24 de April de 2020Délio Damin4 Comentários on Configuring the OPC UA Driver.

An OPC UA Driver implements a communication with an OPC UA server that implements historical and real-time readings, such as EPM. This object can be used as a data source…

Read More

OPC Servers Redundancy in Elipse E3.

15 de October de 20193 de June de 2024Paulo Gustavo SüffertLeave a Comment on OPC Servers Redundancy in Elipse E3.

Question: Is there  any native OPC redundancy tool in the Elipse E3 OPC Driver? How can I use it? If there is none, how can I work around it? Solution:…

Read More

OPC tags timestamp.

25 de March de 201929 de May de 2019Marco Antonio Gomes SilvaLeave a Comment on OPC tags timestamp.

Question: What timestamp is used by TimeStamp property at Elipse E3/Power OPC Client tag? Solution: The timestamp used by this property is the same used one sent by the OPC…

Read More

Communication established correctly in E3Studio, but fails at run time.

25 de March de 20197 de May de 2019Elipse SoftwareLeave a Comment on Communication established correctly in E3Studio, but fails at run time.

Question: Why does the communication properly established via E3Studio fail at run time? Solution: A few reasons for communication failures at run time are: 1. The hardkey or softkey was…

Read More

Using OPC tag groups.

25 de March de 20195 de July de 2019Elipse SoftwareLeave a Comment on Using OPC tag groups.

Question: In an application designed to communicate with 1500 OPC tags, which of the following is the best option for the OPC client: several OPC groups with fewer tags (for…

Read More

Sample simCLP application simulating a PLC via OPC server.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on Sample simCLP application simulating a PLC via OPC server.

Introduction Oftentimes, when developing applications with SCADA software, you will need to perform tests where I/O tags must be either forced or simulated. This article will show you how to…

Read More

KB-31755: Advantages of OPC communication.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-31755: Advantages of OPC communication.

Question: What are the advantages of communicating via OPC client/server? Solution: Some advantages of communicating via OPC are: Drivers’ easy configuration: once the tag base is created in the OPC…

Read More

KB-28611: Importing OPC tags.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28611: Importing OPC tags.

Question: Why is an OPC tag imported from an E3 Server displayed as folder containing several properties? Solution: OPC tags are imported as folders containing its main properties. If necessary,…

Read More

KB-39425: OPC communication not working, even after DCOM has been set up.

25 de March de 201919 de September de 2019Elipse SoftwareLeave a Comment on KB-39425: OPC communication not working, even after DCOM has been set up.

Question: Why is OPC communication working properly in E3Studio, but not when being executed (even after DCOM has been set up)? Solution: This happens because the OPC Server cannot be…

Read More