KB-34142: Changing messages in E3Alarms’s Severity field.

25 de March de 2019Elipse Software2 Comentários on KB-34142: Changing messages in E3Alarms’s Severity field.

Question: How can I display different messages from those defined as default on the E3Alarm‘s Severity field? Solution: To do so, select the Severity field in the E3Alarm‘s properties on…

Read More

KB-31253: Alarm acknowledgment only when there is a user logged in.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-31253: Alarm acknowledgment only when there is a user logged in.

Question: How can I set up the alarms to only allow their acknowledgment when there is a user logged in the application? Solution: To do so, there are two options:…

Read More

Alarms acknowledgement via scripts.

25 de March de 201922 de April de 2019Paulo Gustavo SüffertLeave a Comment on Alarms acknowledgement via scripts.

How can a specific alarm be acknowledged inside E3Alarm via scripts? Alarm acknowledgement via scripts has been a feature of E3 since its version 3.2. To do so, three new…

Read More

BUG-0002873: Area’s name cannot be changed at runtime.

25 de March de 20193 de October de 2024Elipse SoftwareLeave a Comment on BUG-0002873: Area’s name cannot be changed at runtime.

OVERVIEW If an alarm area’s name is changed at runtime, its old name will still be displayed in the alarm’s fields (Area, FullAlarmSourceName). HOW CAN I REPRODUCE THIS PROBLEM? Change…

Read More

BUG-0009880: Active alarms need to be re-acknowledged when Domain is updated.

25 de March de 20193 de October de 2024Elipse SoftwareLeave a Comment on BUG-0009880: Active alarms need to be re-acknowledged when Domain is updated.

OVERVIEW Some alarms will leave their acknowledged status if the AlarmSource is restarted by an update command in the Domain, or via Activate/Deactivate methods. HOW CAN I REPRODUCE THIS PROBLEM?…

Read More

BUG-0008263: After AlarmServer deactivation, E3Alarms does not diplay any alarms anymore.

25 de March de 201922 de January de 2020Elipse SoftwareLeave a Comment on BUG-0008263: After AlarmServer deactivation, E3Alarms does not diplay any alarms anymore.

OVERVIEW If the AlarmServer is deactivated and then reactivated in runtime, the alarms summary becomes empty and is no longer updated. HOW CAN I REPRODUCE THIS PROBLEM? Start up a…

Read More

BUG-0010260: Alarm message remains in the summary if AlarmSource is disabled in E3 Studio.

25 de March de 20199 de September de 2022Elipse SoftwareLeave a Comment on BUG-0010260: Alarm message remains in the summary if AlarmSource is disabled in E3 Studio.

OVERVIEW Alarm messages can remain active in the summary if its corresponding AlarmSource is disabled via Studio, and then the domain is restarted. HOW CAN I REPRODUCE THIS PROBLEM? Stop…

Read More

BUG-0010196: Alarm messages are removed from E3Alarm when Domain stops

25 de March de 2019Elipse SoftwareLeave a Comment on BUG-0010196: Alarm messages are removed from E3Alarm when Domain stops

OVERVIEW E3Alarm‘s alarms summary should keep all messages when Domain stops, but not when it closes. HOW CAN I REPRODUCE THIS PROBLEM? Run the Domain; Activate a certain amount of…

Read More

KB-27418: Storing historic alarms in E3Alarm.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-27418: Storing historic alarms in E3Alarm.

Question: Can E3Alarm store the acknowledged alarms that have already returned to the normal status? That is, is it possible not to remove them from the list, so that they…

Read More

KB-28636: Setting up alarm’s Message column’s width and name.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28636: Setting up alarm’s Message column’s width and name.

Question: How can I set up the alarm’s Message column’s width and name?Solution: Via E3Studio, go to E3Alarm’s properties window, and on Columns tab select the name of the column…

Read More