KB-33841: Configuring tags whose N3 parameter is higher than 65535.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-33841: Configuring tags whose N3 parameter is higher than 65535.

Question: The addressing format in the device is AI:3000019,  but the tag’s N3 parameter only supports values no bigger than 65535. How can I fix this? Solution: BACnet protocol supports…

Read More

KB-23361: IOTag’s TimeStamp assumes the computer’s date/time value when the driver starts.

25 de March de 201924 de February de 2025Elipse SoftwareLeave a Comment on KB-23361: IOTag’s TimeStamp assumes the computer’s date/time value when the driver starts.

Question: When the driver starts, it sets the computer’s TimeStamp for each read value, instead of the remote unit’s TimeStamp. How can I fix this issue, or at least discard…

Read More

Lendo dados de um web service XML.

25 de March de 201910 de November de 2020Cézar Lumiatti TeixeiraLeave a Comment on Lendo dados de um web service XML.

1) Introdução Este artigo demonstra como realizar a coleta de dados de um web service que usa XML como protocolo. Para explicar esta coleta, usaremos um web service que fornece um…

Read More

KB-16839: Operation modes supported by IEC and DNP drivers.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-16839: Operation modes supported by IEC and DNP drivers.

Question: Do IEC and DNP drivers work in full-duplex and half-duplex mode? Solution: Yes. Elipse’s IEC and DNP drivers support both full-duplex and half-duplex modes. The operation mode must be…

Read More

KB-28464: Driver for communication with Atos PMC 4004R PLC.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28464: Driver for communication with Atos PMC 4004R PLC.

Question: Which driver communicates with Atos PMC 4004R PLC? Solution: To establish communication with this PLC, use Atos APR03 driver. This driver allows communication with the following devices: MPC1200, MPC1600,…

Read More

KB-33496: Reading Int16 at PLC MPC4004.05B.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-33496: Reading Int16 at PLC MPC4004.05B.

Question: Is it possible to read data Int16? Solution: Yes, it is. To do so, use function 15 on the PLC tag’s N2.

Read More

KB-34123: N parameters settings for Atos APR03 driver.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-34123: N parameters settings for Atos APR03 driver.

Question: When using Atos APR03 driver, what do the N parameters in a PLC tag mean? Solution: The meaning of each one of these parameter is as follows: N1 –…

Read More

KB-32871: Communication between Micrologix PLC and Elipse E3.

25 de March de 2019Elipse Software4 Comentários on KB-32871: Communication between Micrologix PLC and Elipse E3.

Question: How can I establish communication between Micrologix PLC and Elipse E3? Solution: To do so, use Allen-Bradley ABDF1 driver, and perform one of the following settings:  Use DF1 protocol…

Read More

KB-36111: Driver for communication with Altus Piccolo 106 PLC.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-36111: Driver for communication with Altus Piccolo 106 PLC.

Question: Which driver is used to establish communication with an Altus Piccolo 106 PLC? Solution: This PLC uses Altus ALNET I driver (Alnet 1v2 driver). However, if an ethernet module…

Read More

Sample Application – ASCII Generic Driver.

25 de March de 201926 de April de 2019Elipse SoftwareLeave a Comment on Sample Application – ASCII Generic Driver.

1) Introduction Due to a great number of devices whose communication occurs via ASCII protocols, Elipse Software has developed the ASCII Generic Driver. This driver is used to establish a…

Read More