KB-30330: Configuring serial port when using Siemens’ PC Adpter 5.1 cable connected to a PLC.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-30330: Configuring serial port when using Siemens’ PC Adpter 5.1 cable connected to a PLC.

Question: How can I configure a serial port with a Siemens’ PC Adpter 5.1 cable connected to a PLC S7-300? Solution: To do so, perform these settings in the driver’s…

Read More

KB-33918: Fail when opening screens with E3Alarm or E3Browser

25 de March de 201922 de January de 2020Elipse SoftwareLeave a Comment on KB-33918: Fail when opening screens with E3Alarm or E3Browser

Question: When I try to open a screen with an E3Alarm or an E3Browser on it, it does not open properly, and its display reads exactly like an internet browser…

Read More

KB-29996: Using WriteToFile() command to write on a new line.

25 de March de 20198 de January de 2020Elipse SoftwareLeave a Comment on KB-29996: Using WriteToFile() command to write on a new line.

Question: On an application, WriteToFile() command is being used to write values in a TXT file, but it is not writing in a new line. How can I fix the…

Read More

KB-30265: Changing the default font of a Text object on SCADA.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-30265: Changing the default font of a Text object on SCADA.

Question: Is it possible to change the default font of a Text object on SCADA? Solution: No, it is not, because this is hard-coded on SCADA. So, you must change…

Read More

KB-30029: ASCII communication with Elipse SCADA or E3.

25 de March de 201919 de February de 2024Elipse SoftwareLeave a Comment on KB-30029: ASCII communication with Elipse SCADA or E3.

  Question: Can I establish ASCII communication with Elipse SCADA or E3? Solution: Yes, you can. To do so, use one of the following drivers: ASCII Generic or RS232 Generic.…

Read More

KB-30260: Communication between Domains.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-30260: Communication between Domains.

Question: Can two different domains in Elipse E3 communicate with each other? Solution: Yes. Two possibilities of doing so are: Via OPC Communication Via Remote Domains

Read More

KB-29927: Breaking a line on a MessageBox.

25 de March de 20195 de July de 2019Elipse SoftwareLeave a Comment on KB-29927: Breaking a line on a MessageBox.

Question: How can I break a line on a MessageBox? Solution: To do so, you must write a script using the Chr() function. For example: MessageBox(“phrase line 1″+Chr(13)+Chr(10)+”phrase line 2”…

Read More

KB-29747: Monitoring the communication between Elipse E3 and a PLC.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-29747: Monitoring the communication between Elipse E3 and a PLC.

Question: How can I set up an alarm to be triggered when the communication between the Elipse E3 and a PLC is offline? Solution: There are two different ways to…

Read More

KB-29686: Viewing Driver’s status.

25 de March de 20199 de September de 2019Elipse SoftwareLeave a Comment on KB-29686: Viewing Driver’s status.

Question: How can I view the Driver’s status? Solution: To do so, you must create a tag and configure its parameters as N1=-1, N2=0, N3=0 and N4=2, or import a…

Read More

KB-29619: E3Chart is redrawing data when opening the screen.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-29619: E3Chart is redrawing data when opening the screen.

Question: In an application, the data is being “drawn” by E3Chart, but when leaving the screen and returning to back to it, the chart is erased and it starts to…

Read More