KB-19359: Disabling DateTime field in the Browser.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-19359: Disabling DateTime field in the Browser.

Question: How can I set up DateTime field to not be displayed in the Browser? Solution: To do so, open the Database tab in the Browser’s properties, select the DateTime…

Read More

KB-17743: Displaying a pen’s value when the mouse is on it.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-17743: Displaying a pen’s value when the mouse is on it.

Question: On a Trend Graph plotting historical data, how can I set up a pen’s value to be displayed whenever the mouse is on the pen? Solution:To do so, you…

Read More

KB-16957: Changing a Bitmap’s figure at run time.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-16957: Changing a Bitmap’s figure at run time.

Question: How can I change the figure being displayed on a Bitmap object at run time? Solution: To do so, you must edit the Bitmap’s Filename property. For example: Bitmap1.fileName…

Read More

KB-14451: Setting an animation’s image to keep its original size.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-14451: Setting an animation’s image to keep its original size.

Question: How can I configure an animation’s image to keep its original size? Solution:To do so, click the Adjust image button on General tab of the animation’s properties.

Read More

KB-35701: Objects’ TAB order on a screen.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-35701: Objects’ TAB order on a screen.

Question: How can the objects’ TAB order on a screen be set in an application? Solution: The browsing order via TAB button is set according to the order the objects…

Read More

KB-37100: Generating bitmap of the Trend object on SCADA

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-37100: Generating bitmap of the Trend object on SCADA

Question: How can I generate a bitmap of the Trend object on SCADA? Solution: To do so, just execute the SaveBitmap() function of the Trend object’s Plot item. Example: Plot.SaveBitmap(“Figure.bmp”,…

Read More

KB-36544: Capital letters in a SetPoint.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-36544: Capital letters in a SetPoint.

Question: Is it possible to set up a SetPoint to display characters in all caps? Solution: Yes. To do so, you must write a script using MakeUpper() function, because it…

Read More

KB-36501: CurrentTime not displaying Windows’s time.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-36501: CurrentTime not displaying Windows’s time.

Question: Why is a Display showing incorrect date/time when using CurrentTime attribute? Solution: This may happen because SCADA’s internal clock is delayed/early in relation to the Windows clock. To disable…

Read More

KB-36070: Reading a bar code via supervisory.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-36070: Reading a bar code via supervisory.

Question: Can I read a bar code with a scanner via supervisory? Solution: Yes, you can. To do so, the scanner must have a PS2 connection so it can work…

Read More

KB-36000: Changing the Key Pad displayed in SCADA.

25 de March de 201918 de October de 2019Elipse SoftwareLeave a Comment on KB-36000: Changing the Key Pad displayed in SCADA.

Question: How can I change the Key Pad displayed on SCADA? Solution: To do so, you must uncheck the Enable Key Pad option via Organizer and, via scripts, call another…

Read More