Category: Drivers

KB-32973: Sample Application – Elipse SCADA communicating with S7-200 via M-Prot driver.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-32973: Sample Application – Elipse SCADA communicating with S7-200 via M-Prot driver.

This sample application shows how to access some of the variables from Siemens’ S7-200 PLC via M-Prot driver. Note: this application has been developed with Elipse SCADA v2.29 b092. Attachments:…

Read More

KB-32949: Using a Siemens’ USB cable with M-Prot driver.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-32949: Using a Siemens’ USB cable with M-Prot driver.

Question: Can I establish communication with a PLC via M-Prot driver and a Siemens’ USB cable? Solution: No, you can’t. To communicate using a USB cable, you must use either…

Read More

KB-33868: Communicating with S7-200 via PPI.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-33868: Communicating with S7-200 via PPI.

Question: How can I establish communication with an S7-200 PLC via PPI? Solution: To establish communication with an S7-200 PLC via PPI, you must use version 2.09 (or higher) of…

Read More

KB-34924: Reading a VD in an S7-200 via Ethernet.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-34924: Reading a VD in an S7-200 via Ethernet.

Question: How can an S7-200’s VD20 be read via Ethernet with M-Prot driver? Solution: To establish communication with an S7-200 CP243 via Ethernet, you must set Network field as ISOTCP243.…

Read More

KB-32176: Accessing a bit from a memory byte from a S7-200 at E3.

25 de March de 201916 de September de 2020Elipse SoftwareLeave a Comment on KB-32176: Accessing a bit from a memory byte from a S7-200 at E3.

Question: How can I access a bit from a memory byte from a S7-200 at E3? Solution: To do so, set a tag’s N2 parameter as 108, and its N4…

Read More

Reading and writing bits with M-Prot driver.

25 de March de 2019Elipse SoftwareLeave a Comment on Reading and writing bits with M-Prot driver.

Question: Can the bit from a digital input be read? Can Bool-type tags be used? Solution: No; this can only be done indirectly. To read/write a single bit, the whole…

Read More

KB-34883: Sending SMS messages via E3.

25 de March de 201910 de June de 2019Elipse SoftwareLeave a Comment on KB-34883: Sending SMS messages via E3.

Question: Is there a driver to send SMS messages via E3? Solution: Yes, there is. To do so, you can use the driver Siemens M20. If you are not equipped…

Read More

KB-28227: Settings for Omron FINS driver.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-28227: Settings for Omron FINS driver.

Question: What settings are required to establish communication between Omron FINS driver and a PLC? Solution: In the example below, the PLC’s model is CJ1M – CPU13-ETN. This CPU’s model…

Read More

KB-31949: Reading negative numbers with FINS driver.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-31949: Reading negative numbers with FINS driver.

Question: How can I set FINS driver to read negative numbers? Solution: According to the driver’s manual, N2 parameter’s format is TANN. In this case (N2=0111), data type is either…

Read More

KB-27186: Communicating with PLC S7200 via USB serial converter.

25 de March de 2019Elipse SoftwareLeave a Comment on KB-27186: Communicating with PLC S7200 via USB serial converter.

Question: How can I establish communication with a PLC S7200 by using a USB serial converter? Solution: To do so, since the driver will always keep its parity as EVEN,…

Read More