KB-28909: Driver licenses for communication via ISOTCP.

25 de março de 2019Elipse SoftwareDeixe um comentário on KB-28909: Driver licenses for communication via ISOTCP.

Question: How many driver licenses are necessary to communicate with two PLCs via ISOTCP? Solution: To do so, you need two Driver licenses.

Leia Mais

KB-28952: Showing all decimal places in a Display.

25 de março de 201918 de outubro de 2019Elipse SoftwareDeixe um comentário on KB-28952: Showing all decimal places in a Display.

Question: How can I show all decimal places on a SCADA’s Display, and not just its rounded up value? Solution: To do so, you must set up the Precision property…

Leia Mais

KB-28575: Accessing an Altus OPC Server installed in a different computer.

25 de março de 2019Elipse SoftwareDeixe um comentário on KB-28575: Accessing an Altus OPC Server installed in a different computer.

Question: To access the Altus OPC Server Driver from a different PC, do I need to have an OPC Driver installed in my own computer? Or can I access the…

Leia Mais

KB-28793: Communication with Moeller’s XC-201 PLC .

25 de março de 2019Elipse SoftwareDeixe um comentário on KB-28793: Communication with Moeller’s XC-201 PLC .

Question: Which drivers communicate with Moeller’s CPU XC-201? Solution: There is no driver to communicate with this PLC. CPU XC-201 is an OPC Server, so the communication happens via OPC.

Leia Mais

KB-28868: Setting up the Viewer to work with four monitors.

25 de março de 201924 de novembro de 2022Elipse SoftwareDeixe um comentário on KB-28868: Setting up the Viewer to work with four monitors.

Question: How can I set the Viewer’s resolution to be used with four monitors in 2×2 format, each monitor with 2560 x 1600? Solution: To do so, you must sum…

Leia Mais

KB-28527: Information exchange between E3 servers.

25 de março de 201918 de agosto de 2020Elipse SoftwareDeixe um comentário on KB-28527: Information exchange between E3 servers.

Question: Can I use OPC communication to exchange information between two E3 applications? Solution: Yes, you can, but we don’t recommend doing so: when there is a network problem, Windows…

Leia Mais

KB-28571: SCADA full screen closed with Ctrl+F4.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-28571: SCADA full screen closed with Ctrl+F4.

Question: Why is a SCADA full screen being closed when pressing Ctrl+F4? Solution: This is SCADA’s standard behavior. To change it, you can use the Ctrl+F4 combination in an OnKeyPress()…

Leia Mais

KB-28535: Sharing directories for Remote Domains.

25 de março de 2019Elipse SoftwareDeixe um comentário on KB-28535: Sharing directories for Remote Domains.

Question: In the Domain File, why do I need to inform the shared directory where application to be accessed is? Solution: You must do this so that E3 will access…

Leia Mais

KB-28296: Maximum amount of Historic fields when using Access DB.

25 de março de 2019Elipse SoftwareDeixe um comentário on KB-28296: Maximum amount of Historic fields when using Access DB.

Question: What is the maximum amount of Historic fields when using Access DB? Solution: You can use up to 127 fields: for each field created in the Historic, another one…

Leia Mais

KB-28340: Exporting screens from Elipse SCADA to Elipse E3.

25 de março de 201918 de outubro de 2019Elipse SoftwareDeixe um comentário on KB-28340: Exporting screens from Elipse SCADA to Elipse E3.

Question: How can I export screens from Elipse SCADA to Elipse E3? Are scripts exported too? Solution: To do so, access Elipse SCADA, open the Organizer (Alt+O), select the desired…

Leia Mais