{"id":3659,"date":"2019-03-25T17:45:21","date_gmt":"2019-03-25T20:45:21","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/parameterizing-iec-104s-io-tags-via-strings\/"},"modified":"2019-06-10T13:50:04","modified_gmt":"2019-06-10T16:50:04","slug":"parameterizing-iec-104s-io-tags-via-strings","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/","title":{"rendered":"Parameterizing IEC 104&#039;s I\/O tags via strings."},"content":{"rendered":"<div align=\"justify\">\n<p><b>Question:<\/b><\/p>\n<p>Sometimes, the device&#8217;s I\/O point address is higher than 65535, which surpasses the 2-octet value supported by conventional parameterization (<i>N <\/i>parameters). In this case, how can I parameterize the driver&#8217;s I\/O tags?<\/p>\n<p><b>Solution:<\/b><\/p>\n<p>To do so, you have to parameterize the driver&#8217;s I\/O tags via strings at <i>ParamDevice <\/i>and <i>ParamItem <\/i>fields. This parameterization was implemented at the driver to support addresses longer than 2 bytes that are required by a few devices.<\/p>\n<p>To parameterize tags via strings, you must first reset the <i>N <\/i>parameters. Then place the PLC address at <i>ParamDevice <\/i>field and the tag address at <i>ParamItem<\/i>.<\/p>\n<p>The syntax at <i>ParamItem <\/i>field for monitoring data is:<br \/>\n<b><br \/>\n:[]<br \/>\n<\/b><br \/>\nWhere:<\/p>\n<p><b><\/b>\u00a0 is the datatype&#8217;s mnemonic: SP, DP, ST, BO, MEn, MEs, MEf. The colon (:) separating the mnemonic from the object&#8217;s address is optional. The table below displays the monitoring datatypes and their mnemonic symbols:<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem1Enu.png\" alt=\"\" width=\"500\" height=\"580\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b><br \/>\n<\/b>is the tag&#8217;s address, which could be displayed in one of the following formats:<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem2Enu.png\" alt=\"\" width=\"500\" height=\"302\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b><\/b> is an optional character that sets up the priority with which data is sent (in case of a slave driver):<\/p>\n<ul>\n<li>when the character is omitted, data is sent with <b>default <\/b>priority (digital data with high priority, analog data with low priority; default priority can be configured at the driver&#8217;s settings)<\/li>\n<li>when the character is an exclamation point (!) , data is sent with <b>high <\/b>priority. Example:\u00a0 SP:255!<\/li>\n<li>when the character is a less-than sign (<), data is only sent in the next general query. Example: SP:255<<\/li>\n<li>when the character is an equals sign (=), data is sent with <b>low <\/b>priority . Example:\u00a0 SP:255=<\/li>\n<\/ul>\n<p>The syntax at <i>ParamItem <\/i>field for (master driver only) commands is:<\/p>\n<p><b>:.[()]<\/b><\/p>\n<p>Where:<\/p>\n<p><b>\u00a0<\/b> is the datatype&#8217;s mnemonic: CBO, CBOt, DC, DCt, RC, RCt, SC, SCt, SEn, SEnt, SEs, SEst, SEf, SEft. The colon (:) separating the mnemonic from the object&#8217;s address is optional. The table below displays the monitoring datatypes and their mnemonic symbols:<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem3Enu.png\" alt=\"\" width=\"500\" height=\"550\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b>\u00a0<\/b> is the tag&#8217;s address, which could be displayed in one of the following formats:<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem4Enu.png\" alt=\"\" width=\"500\" height=\"317\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b><\/b> is the command type, which could be:<\/p>\n<ul>\n<li><b>Select<\/b>: selects the command<\/li>\n<li><b>Execute<\/b>: executes the command<\/li>\n<li><b>Deactivate<\/b>: deactivates a previously sent selection<\/li>\n<\/ul>\n<p><b><\/b> is an optional parameter, to be informed between parenthesis. The available options are:<\/p>\n<ul>\n<li><b>(LongPulse)<\/b>: sends a long pulse<\/li>\n<li><b>(ShortPulse)<\/b>: sends a short pulse<\/li>\n<li><b>(PersistentOutput)<\/b>: generates an output with persistent value<\/li>\n<li><b>Omitted<\/b>: no qualifier specified<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Question: Sometimes, the device&#8217;s I\/O point address is higher than 65535, which surpasses the 2-octet value supported by conventional parameterization (N parameters). In this case, how can I parameterize the&hellip;<\/p>\n","protected":false},"author":15,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[795],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Parameterizing IEC 104&#039;s I\/O tags via strings. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Parameterizing IEC 104&#039;s I\/O tags via strings.\" \/>\n<meta property=\"og:description\" content=\"Question: Sometimes, the device&#8217;s I\/O point address is higher than 65535, which surpasses the 2-octet value supported by conventional parameterization (N parameters). In this case, how can I parameterize the&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:45:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-06-10T16:50:04+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem1Enu.png\" \/>\n<meta name=\"author\" content=\"Gabriel Manara\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Gabriel Manara\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\"},\"author\":{\"name\":\"Gabriel Manara\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/62f73726da552619d723db2fd82e3530\"},\"headline\":\"Parameterizing IEC 104&#039;s I\/O tags via strings.\",\"datePublished\":\"2019-03-25T20:45:21+00:00\",\"dateModified\":\"2019-06-10T16:50:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\"},\"wordCount\":628,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"IEC 870-5-101\/102\/104 (Master,Slave)\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\",\"url\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\",\"name\":\"[:pt]Parameterizing IEC 104's I\/O tags via strings.[:en]Parameterizing IEC 104&#039;s I\/O tags via strings.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:45:21+00:00\",\"dateModified\":\"2019-06-10T16:50:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Parameterizing IEC 104&#039;s I\/O tags via strings.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/62f73726da552619d723db2fd82e3530\",\"name\":\"Gabriel Manara\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8f08450bea42667090b5d00999160306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8f08450bea42667090b5d00999160306?s=96&d=mm&r=g\",\"caption\":\"Gabriel Manara\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/manara\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Parameterizing IEC 104&#039;s I\/O tags via strings. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]Parameterizing IEC 104's I\/O tags via strings.[:en]Parameterizing IEC 104&#039;s I\/O tags via strings.[:] - Elipse Knowledgebase","og_description":"Question: Sometimes, the device&#8217;s I\/O point address is higher than 65535, which surpasses the 2-octet value supported by conventional parameterization (N parameters). In this case, how can I parameterize the&hellip;","og_url":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:45:21+00:00","article_modified_time":"2019-06-10T16:50:04+00:00","og_image":[{"url":"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5351EN\/Imagem1Enu.png"}],"author":"Gabriel Manara","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Gabriel Manara","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/"},"author":{"name":"Gabriel Manara","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/62f73726da552619d723db2fd82e3530"},"headline":"Parameterizing IEC 104&#039;s I\/O tags via strings.","datePublished":"2019-03-25T20:45:21+00:00","dateModified":"2019-06-10T16:50:04+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/"},"wordCount":628,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["IEC 870-5-101\/102\/104 (Master,Slave)"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/","url":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/","name":"[:pt]Parameterizing IEC 104's I\/O tags via strings.[:en]Parameterizing IEC 104&#039;s I\/O tags via strings.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:45:21+00:00","dateModified":"2019-06-10T16:50:04+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/en\/parameterizing-iec-104s-io-tags-via-strings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"Parameterizing IEC 104&#039;s I\/O tags via strings."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/62f73726da552619d723db2fd82e3530","name":"Gabriel Manara","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8f08450bea42667090b5d00999160306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8f08450bea42667090b5d00999160306?s=96&d=mm&r=g","caption":"Gabriel Manara"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/manara\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3659"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3659"}],"version-history":[{"count":2,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3659\/revisions"}],"predecessor-version":[{"id":7111,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3659\/revisions\/7111"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3659"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3659"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3659"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}