{"id":3606,"date":"2019-03-25T17:45:06","date_gmt":"2019-03-25T20:45:06","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/"},"modified":"2019-06-10T14:14:57","modified_gmt":"2019-06-10T17:14:57","slug":"migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/","title":{"rendered":"Migrating previous versions of Siemens Prodave driver to version 2.0.1."},"content":{"rendered":"<div align=\"justify\">\n<p>After Siemens Prodave driver&#8217;s latest update (v2.0.1), the following improvements can stand out:<\/p>\n<ul>\n<li>Migration to IOKit 2.00<\/li>\n<li>Communication with Siemens Prodave MPI\/IE v6.x software<\/li>\n<li>Adapted to run on Windows 7<\/li>\n<\/ul>\n<p>A few points on the driver&#8217;s current version:<\/p>\n<p>1. The driver can migrate from version 1.xx to 2.0.1 with tags and links settings compatibility at <b>Extra Settings<\/b>.<\/p>\n<p>2. Tags can be set up via strings (<b>Symbolic Address<\/b>).<\/p>\n<p>3. Prodave MPI\/IE v6.x software works from Windows XP operating system, and is only compatible with Siemens Prodave v2.0.1 driver.<\/p>\n<p>4.\u00a0 Prodave v 5.6 (or lower) software does <b>not <\/b>work from Windows 7 operating system and does not work with this driver&#8217;s latest version. In this case, you must use Siemens Prodave driver version 1.01.<\/p>\n<p>5. This driver can be used with Siemens USB adaptors, being an alternative MProt for this type of topology.<\/p>\n<p>6. From version 2.0.1 on, you don&#8217;t have to install the Siemens software in order to load and initialize the driver, and its settings can be done on the properties window. On the previous version (1.xx), the driver wasn&#8217;t loaded, because it depended on the installation. However, if the version 2.0.1 driver is initialized with no Siemens software installed, there will be a communication error and the log will indicate the Prodave MPI\/IE v6.x software was not correctly installed.<\/p>\n<p><b>NOTE<\/b>: Further details can be obtained at this version&#8217;s Help.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>After Siemens Prodave driver&#8217;s latest update (v2.0.1), the following improvements can stand out: Migration to IOKit 2.00 Communication with Siemens Prodave MPI\/IE v6.x software Adapted to run on Windows 7&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[819],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Migrating previous versions of Siemens Prodave driver to version 2.0.1. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Migrating previous versions of Siemens Prodave driver to version 2.0.1.\" \/>\n<meta property=\"og:description\" content=\"After Siemens Prodave driver&#8217;s latest update (v2.0.1), the following improvements can stand out: Migration to IOKit 2.00 Communication with Siemens Prodave MPI\/IE v6.x software Adapted to run on Windows 7&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:45:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-06-10T17:14:57+00:00\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"Migrating previous versions of Siemens Prodave driver to version 2.0.1.\",\"datePublished\":\"2019-03-25T20:45:06+00:00\",\"dateModified\":\"2019-06-10T17:14:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\"},\"wordCount\":233,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"Siemens Prodave\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\",\"url\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\",\"name\":\"[:pt]Migrating previous versions of Siemens Prodave driver to version 2.0.1.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:45:06+00:00\",\"dateModified\":\"2019-06-10T17:14:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Migrating previous versions of Siemens Prodave driver to version 2.0.1.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Migrating previous versions of Siemens Prodave driver to version 2.0.1. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]Migrating previous versions of Siemens Prodave driver to version 2.0.1.[:] - Elipse Knowledgebase","og_description":"After Siemens Prodave driver&#8217;s latest update (v2.0.1), the following improvements can stand out: Migration to IOKit 2.00 Communication with Siemens Prodave MPI\/IE v6.x software Adapted to run on Windows 7&hellip;","og_url":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:45:06+00:00","article_modified_time":"2019-06-10T17:14:57+00:00","author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"Migrating previous versions of Siemens Prodave driver to version 2.0.1.","datePublished":"2019-03-25T20:45:06+00:00","dateModified":"2019-06-10T17:14:57+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/"},"wordCount":233,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["Siemens Prodave"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/","url":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/","name":"[:pt]Migrating previous versions of Siemens Prodave driver to version 2.0.1.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:45:06+00:00","dateModified":"2019-06-10T17:14:57+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/en\/migrating-previous-versions-of-siemens-prodave-driver-to-version-2-0-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"Migrating previous versions of Siemens Prodave driver to version 2.0.1."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3606"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3606"}],"version-history":[{"count":1,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3606\/revisions"}],"predecessor-version":[{"id":7155,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3606\/revisions\/7155"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3606"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3606"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}