{"id":3548,"date":"2019-03-25T17:44:49","date_gmt":"2019-03-25T20:44:49","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/"},"modified":"2019-10-18T10:55:58","modified_gmt":"2019-10-18T13:55:58","slug":"printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/","title":{"rendered":"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA."},"content":{"rendered":"<div align=\"justify\">\n<p>To print a report in Windows NT at normal speed without needing to leave Elipse SCADA, you must create a RAM tag called <b>Flag <\/b>and a Chrono tag called <b>Counter<\/b>, which will work as printing controllers. The Chrono tag must be set up as follows:<\/p>\n<ul>\n<li><i>Preset <\/i>event: 10 seconds (you can increase this time according to printing time)<\/li>\n<li>Increment: 1 second<\/li>\n<li>Don&#8217;t start the counter when running the application<\/li>\n<li>Reset counter when it&#8217;s on<\/li>\n<li>All other options must remain unchecked<\/li>\n<\/ul>\n<p>Then, create a script at the Chrono tag&#8217;s <i>OnPreset <\/i>event containing the following command:<\/p>\n<p><span style=\"font-family: Courier New;\">Flag = 0<\/span><\/p>\n<p>and another script at <i>OnEnabled <\/i>event with the following command:<\/p>\n<p><span style=\"font-family: Courier New;\">Flag = 1<\/span><\/p>\n<p>Then go to the screen with this command to print the report (or access the <b>Application <\/b>item inside the Organizer), create a script at <i>WhileRunning <\/i>event to be executed every 1000 ms, and type the following command:<\/p>\n<p><span style=\"font-family: Courier New;\">If Flag == 1<br \/>\nSleep(0.2)<br \/>\nendif<\/span><\/p>\n<p>Finally, access the printing script (where the report&#8217;s <i>Print()<\/i> command is) and type the following command right after <i>Print()<\/i>:<\/p>\n<p><span style=\"font-family: Courier New;\">Counter.enabled = 1<br \/>\n<\/span><br \/>\n<b>NOTE<\/b>: Some printers may not be able to print when Elipse SCADA is running (such as Epson Stylus Color, for example). To fix this, you must set up the parallel port (via BIOS) as <b>ECP <\/b>(Extended Capabilities Port) mode.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>To print a report in Windows NT at normal speed without needing to leave Elipse SCADA, you must create a RAM tag called Flag and a Chrono tag called Counter,&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[770,776],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.\" \/>\n<meta property=\"og:description\" content=\"To print a report in Windows NT at normal speed without needing to leave Elipse SCADA, you must create a RAM tag called Flag and a Chrono tag called Counter,&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:44:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-10-18T13:55:58+00:00\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.\",\"datePublished\":\"2019-03-25T20:44:49+00:00\",\"dateModified\":\"2019-10-18T13:55:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\"},\"wordCount\":441,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"Elipse Scada\",\"Reports\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\",\"url\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\",\"name\":\"[:pt]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:en]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:44:49+00:00\",\"dateModified\":\"2019-10-18T13:55:58+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:en]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:] - Elipse Knowledgebase","og_description":"To print a report in Windows NT at normal speed without needing to leave Elipse SCADA, you must create a RAM tag called Flag and a Chrono tag called Counter,&hellip;","og_url":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:44:49+00:00","article_modified_time":"2019-10-18T13:55:58+00:00","author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.","datePublished":"2019-03-25T20:44:49+00:00","dateModified":"2019-10-18T13:55:58+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/"},"wordCount":441,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["Elipse Scada","Reports"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/","url":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/","name":"[:pt]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:en]Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:44:49+00:00","dateModified":"2019-10-18T13:55:58+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/en\/printing-a-report-in-windows-nt-at-normal-speed-without-needing-to-leave-elipse-scada\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"Printing a report in Windows NT at normal speed without needing to leave Elipse SCADA."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3548"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3548"}],"version-history":[{"count":1,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3548\/revisions"}],"predecessor-version":[{"id":7439,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3548\/revisions\/7439"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}