{"id":3492,"date":"2019-03-25T17:44:33","date_gmt":"2019-03-25T20:44:33","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/"},"modified":"2019-10-18T09:47:43","modified_gmt":"2019-10-18T12:47:43","slug":"kb28888-showing-only-one-alarm-group-at-elipse-scada","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/","title":{"rendered":"KB-28888: Showing only one alarm group at Elipse SCADA."},"content":{"rendered":"<div align=\"justify\"><b>Question:<\/b><\/p>\n<p>I have several screens in my application, each one with its own <b>Alarms <\/b>object. How can I have each of these objects showing only its own screen&#8217;s alarms?<\/p>\n<p><b>Solution:<\/b><\/p>\n<p>At the Organizer, access Alarms item and create an alarm group. When setting up the alarms in the tags, configure the group to which it will belong. After that, set up which alarm group will be displayed in each <b>Alarms <\/b>object.<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Question: I have several screens in my application, each one with its own Alarms object. How can I have each of these objects showing only its own screen&#8217;s alarms? Solution:&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[779,770],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>KB-28888: Showing only one alarm group at Elipse SCADA. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KB-28888: Showing only one alarm group at Elipse SCADA.\" \/>\n<meta property=\"og:description\" content=\"Question: I have several screens in my application, each one with its own Alarms object. How can I have each of these objects showing only its own screen&#8217;s alarms? Solution:&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:44:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-10-18T12:47:43+00:00\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"KB-28888: Showing only one alarm group at Elipse SCADA.\",\"datePublished\":\"2019-03-25T20:44:33+00:00\",\"dateModified\":\"2019-10-18T12:47:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\"},\"wordCount\":164,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"Alarms\",\"Elipse Scada\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\",\"url\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\",\"name\":\"[:pt]KB-28888: Showing only one alarm group at Elipse SCADA.[:en]KB-28888: Showing only one alarm group at Elipse SCADA.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:44:33+00:00\",\"dateModified\":\"2019-10-18T12:47:43+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KB-28888: Showing only one alarm group at Elipse SCADA.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KB-28888: Showing only one alarm group at Elipse SCADA. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]KB-28888: Showing only one alarm group at Elipse SCADA.[:en]KB-28888: Showing only one alarm group at Elipse SCADA.[:] - Elipse Knowledgebase","og_description":"Question: I have several screens in my application, each one with its own Alarms object. How can I have each of these objects showing only its own screen&#8217;s alarms? Solution:&hellip;","og_url":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:44:33+00:00","article_modified_time":"2019-10-18T12:47:43+00:00","author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"KB-28888: Showing only one alarm group at Elipse SCADA.","datePublished":"2019-03-25T20:44:33+00:00","dateModified":"2019-10-18T12:47:43+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/"},"wordCount":164,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["Alarms","Elipse Scada"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/","url":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/","name":"[:pt]KB-28888: Showing only one alarm group at Elipse SCADA.[:en]KB-28888: Showing only one alarm group at Elipse SCADA.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:44:33+00:00","dateModified":"2019-10-18T12:47:43+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/en\/kb28888-showing-only-one-alarm-group-at-elipse-scada\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"KB-28888: Showing only one alarm group at Elipse SCADA."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3492"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3492"}],"version-history":[{"count":1,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3492\/revisions"}],"predecessor-version":[{"id":7479,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3492\/revisions\/7479"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}