{"id":3408,"date":"2019-03-25T17:44:09","date_gmt":"2019-03-25T20:44:09","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/"},"modified":"2019-07-05T15:31:49","modified_gmt":"2019-07-05T18:31:49","slug":"kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/","title":{"rendered":"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP."},"content":{"rendered":"<p align=\"justify\"><b>Question:<\/b><\/p>\n<p align=\"justify\">How can I fix the communication issues of user-generated tags in Elipse E3 or Elipse SCADA by using ABCIP and RSLogix driver with firmware v. 21?<\/p>\n<p align=\"justify\"><b>Solution:<\/b><\/p>\n<p align=\"justify\">To do so, you must first update the driver to its latest version, because older versions of the driver don&#8217;t implement functionalities added to more recent firmwares.<\/p>\n<div align=\"justify\">Then, set up the <b>External Access<\/b><br \/>\nparameter of the tag created in the device so that the Elipse E3 or Elipse SCADA will be able to both read and write in this address, according to the figure below.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5089\/1.png\" alt=\"\" width=\"500\" height=\"193\" align=\"Baseline\" border=\"0\" \/><br \/>\n<span id=\"anchor_div\"> <\/span><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Question: How can I fix the communication issues of user-generated tags in Elipse E3 or Elipse SCADA by using ABCIP and RSLogix driver with firmware v. 21? Solution: To do&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[790],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.\" \/>\n<meta property=\"og:description\" content=\"Question: How can I fix the communication issues of user-generated tags in Elipse E3 or Elipse SCADA by using ABCIP and RSLogix driver with firmware v. 21? Solution: To do&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:44:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-07-05T18:31:49+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5089\/1.png\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.\",\"datePublished\":\"2019-03-25T20:44:09+00:00\",\"dateModified\":\"2019-07-05T18:31:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\"},\"wordCount\":103,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"Allen-Bradley Ethernet\/IP (ABCIP)\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\",\"url\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\",\"name\":\"[:pt]KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:44:09+00:00\",\"dateModified\":\"2019-07-05T18:31:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.[:] - Elipse Knowledgebase","og_description":"Question: How can I fix the communication issues of user-generated tags in Elipse E3 or Elipse SCADA by using ABCIP and RSLogix driver with firmware v. 21? Solution: To do&hellip;","og_url":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:44:09+00:00","article_modified_time":"2019-07-05T18:31:49+00:00","og_image":[{"url":"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID5089\/1.png"}],"author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.","datePublished":"2019-03-25T20:44:09+00:00","dateModified":"2019-07-05T18:31:49+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/"},"wordCount":103,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["Allen-Bradley Ethernet\/IP (ABCIP)"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/","url":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/","name":"[:pt]KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:44:09+00:00","dateModified":"2019-07-05T18:31:49+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/en\/kb65118-communicating-with-rslogix-firmware-21-plc-via-driver-abcip\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"KB-65118: Communicating with RSLogix Firmware 21 PLC via driver ABCIP."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3408"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3408"}],"version-history":[{"count":1,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3408\/revisions"}],"predecessor-version":[{"id":7544,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3408\/revisions\/7544"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3408"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3408"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3408"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}