{"id":3046,"date":"2019-03-25T17:42:26","date_gmt":"2019-03-25T20:42:26","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/"},"modified":"2024-03-28T15:06:41","modified_gmt":"2024-03-28T18:06:41","slug":"uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/","title":{"rendered":"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes."},"content":{"rendered":"<div align=\"justify\">\n<p><b>1. Introdu\u00e7\u00e3o<\/b><\/p>\n<p>Visando a melhoria na disponibilidade do sistema e sua toler\u00e2ncia a falhas, \u00e9 comum a escolha de sistemas SCADA com arquitetura redundante, tanto para os servidores quanto para as placas de rede e demais equipamentos presentes.<\/p>\n<p>Uma arquitetura redundante t\u00edpica pode ser observada no esquema abaixo:<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%20Rede.jpg\" alt=\"\" width=\"500\" height=\"310\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>Partindo deste cen\u00e1rio, \u00e9 importante fazer algumas considera\u00e7\u00f5es sobre o modo de funcionamento do Hot Standby, bem como indicar sua correta configura\u00e7\u00e3o nestas condi\u00e7\u00f5es de uso.<br \/>\nA configura\u00e7\u00e3o do Hot Standby \u00e9 baseada nos nomes das m\u00e1quinas servidoras e em IPs de integridade para identificar os estados de cada servidor. A partir destas informa\u00e7\u00f5es, o servidor toma a iniciativa de se tornar ativo ou ir para a reserva.<\/p>\n<p>Basicamente, cada servidor verifica o seu par e os IPs de integridade que est\u00e3o presentes na rede, conforme as regras descritas na tabela abaixo:<\/p>\n<div align=\"center\"><a href=\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/03\/3046\/1_.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-16014\" src=\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/03\/3046\/1_.png\" alt=\"\" width=\"428\" height=\"194\" srcset=\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/03\/3046\/1_.png 428w, https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/03\/3046\/1_-300x136.png 300w\" sizes=\"(max-width: 428px) 100vw, 428px\" \/><\/a><\/div>\n<p>Como cada nome de m\u00e1quina est\u00e1 vinculado a um \u00fanico IP, n\u00e3o \u00e9 poss\u00edvel configurar estes servidores com dois IPs distintos, um em cada placa de rede, pois isto inviabilizaria o funcionamento do hot-standby. A presen\u00e7a de mais de um IP no mesmo servidor poderia gerar uma situa\u00e7\u00e3o onde nenhum servidor encontraria o seu par, mas ambos continuariam acessando os IPs de integridade quando uma das placas de rede deixasse de responder; ou ent\u00e3o eles continuariam acessando as m\u00e1quinas parceiras, mas n\u00e3o os IPs de integridade. Em decorr\u00eancia, poder\u00edamos ter situa\u00e7\u00f5es onde os dois servidores poderiam entrar em estado Ativo, ou ent\u00e3o ambos irem para Reserva.<\/p>\n<p>Para evitar este tipo de situa\u00e7\u00e3o, \u00e9 recomendado utilizar placas de rede com suporte ao NIC Team. A maioria de servidores j\u00e1 possui este tipo de placa, como, por exemplo, modelos de placa das marcas Intel e Broadcom.<\/p>\n<p><b>2. Configura\u00e7\u00e3o do NIC TEAM<\/b><\/p>\n<p>No exemplo a seguir, criaremos o team baseado em uma placa da Intel, modelo Intel Pro 1000 PT Dual Port Gigabit. Siga estes procedimentos:<\/p>\n<p>1. Acesse o <b>Gerenciador de Dispositivos<\/b> e selecione a pasta de <b>Adaptadores de Rede<\/b>.<\/p>\n<p>2. Acesse as propriedades da placa de rede com suporte ao team.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%201.jpg\" alt=\"\" width=\"491\" height=\"552\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>3. Acesse a aba <b>Teaming <\/b>e habilite a op\u00e7\u00e3o <i><b>Team this adapter with others adapters<\/b><\/i>.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%202.jpg\" alt=\"\" width=\"414\" height=\"513\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>4. Crie um novo team atrav\u00e9s do bot\u00e3o <i><b>New Team<\/b><\/i>.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%203.jpg\" alt=\"\" width=\"500\" height=\"349\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>5. Na pr\u00f3xima janela, selecione as placas que v\u00e3o fazer parte do team.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%204.jpg\" alt=\"\" width=\"500\" height=\"349\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>6. Na janela seguinte, selecione a op\u00e7\u00e3o <i><b>Adapter Fault Tolerance<\/b><\/i> como tipo de team.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%205.jpg\" alt=\"\" width=\"500\" height=\"349\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>7. Passe para a pr\u00f3xima janela e finalize a configura\u00e7\u00e3o.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%206.jpg\" alt=\"\" width=\"500\" height=\"349\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>8. Note que foi criado um novo adaptador de rede com o nome do team definido.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%207.jpg\" alt=\"\" width=\"500\" height=\"553\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b>3. Configura\u00e7\u00e3o Rede<\/b><\/p>\n<p>Dependendo da estrutura de TI instalada, devemos seguir por um dos dois caminhos a seguir: 1) caso a rede possua um Dom\u00ednio de rede com servidor DNS; ou 2) caso n\u00e3o exista um dom\u00ednio, mas apenas um grupo de trabalho.<\/p>\n<p><b>3.1. Dom\u00ednio com DNS<\/b><\/p>\n<p>No sistema, o servidor DNS \u00e9 respons\u00e1vel por manter uma lista com os nomes de m\u00e1quinas e por distribuir IPs para estes nomes. Com isto, cada m\u00e1quina recebe o seu IP de forma autom\u00e1tica, sendo necess\u00e1rio apenas confirmar que o adaptador de rede est\u00e1 habilitado para ser configurado automaticamente, conforme as instru\u00e7\u00f5es a seguir:<\/p>\n<p>1. Acesse a janela contendo os adaptadores de Rede.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%208.jpg\" alt=\"\" width=\"490\" height=\"378\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>2. Acesse as propriedades do adaptador com o team criado.<\/p>\n<p>3. Acesse as propriedades da op\u00e7\u00e3o <i><b>Internet Protocol Version 4 (TCP\/IPv4)<\/b><\/i>.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%209.jpg\" alt=\"\" width=\"377\" height=\"475\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>4. Verifique se a op\u00e7\u00e3o <i><b>Obtain an IP address automatically<\/b><\/i> da aba <b>Geral <\/b>est\u00e1 habilitada.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%2010.jpg\" alt=\"\" width=\"414\" height=\"462\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b>3.2. Grupo de Trabalho sem DNS<\/b><\/p>\n<p>Quando n\u00e3o possu\u00edmos um servidor DNS no sistema, \u00e9 necess\u00e1rio configurar manualmente o IP da rede, al\u00e9m de cadastrar em cada m\u00e1quina a rela\u00e7\u00e3o de nomes e IPs de todas as m\u00e1quinas da rede.<\/p>\n<p><b>3.2.1. Configurando o IP manualmente<\/b><\/p>\n<p>1. Siga os passos 1, 2 e 3 do item 3.1.<\/p>\n<p>2. Na janela de propriedades de <i><b>Internet Protocol Version 4 (TCP\/IPv4)<\/b><\/i>, configure a op\u00e7\u00e3o <i><b>Use the following IP address<\/b><\/i> na aba <b>Geral<\/b>. Deve-se utilizar um n\u00famero de IP dispon\u00edvel na rede.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%2011.jpg\" alt=\"\" width=\"414\" height=\"462\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b>3.2.2. Cadastro do nome e IP da m\u00e1quina<\/b><\/p>\n<p>O cadastro do nome da m\u00e1quina, e seu respectivo IP, \u00e9 feito no arquivo hosts, presente no diret\u00f3rio <span style=\"font-family: Courier New;\">C:\\Windows\\System32\\Drivers\\etc\\<\/span><\/p>\n<p>No pr\u00f3prio arquivo existe a documenta\u00e7\u00e3o de como proceder com a configura\u00e7\u00e3o, mas basicamente basta adicionar ao seu final uma nova linha com o IP e o respectivo nome da m\u00e1quina. Uma nova linha deve ser criada para cada servidor que vai participar do Hot-Standby.<\/p>\n<p>Esta mesma configura\u00e7\u00e3o deve ser replicada em todos os computadores envolvidos na aplica\u00e7\u00e3o, nos servidores Elipse e nas m\u00e1quinas Viewer.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%2012.jpg\" alt=\"\" width=\"500\" height=\"426\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p><b>3.2.3. Configura\u00e7\u00e3o Hot-Standby<\/b><\/p>\n<p>A configura\u00e7\u00e3o de Hot-Standby deve ser feita conforme descrito no manual do produto; por\u00e9m, uma pr\u00e1tica aconselh\u00e1vel para sistemas com rede reduntante \u00e9 cadastrar diversos IPs de integridade na configura\u00e7\u00e3o.<\/p>\n<div align=\"center\"><img loading=\"lazy\" title=\"\" src=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%2013%20Nova.png\" alt=\"\" width=\"500\" height=\"430\" align=\"Baseline\" border=\"0\" \/><\/div>\n<p>Esta configura\u00e7\u00e3o torna a solu\u00e7\u00e3o mais segura, pois os servidores s\u00f3 v\u00e3o considerar que a rede est\u00e1 com problemas (ou inacess\u00edvel) se todos estes IPs pararem de responder (ou estiverem inacess\u00edveis), evitando assim que uma falha de um equipamento de integridade interfira no sistema supervis\u00f3rio.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>1. Introdu\u00e7\u00e3o Visando a melhoria na disponibilidade do sistema e sua toler\u00e2ncia a falhas, \u00e9 comum a escolha de sistemas SCADA com arquitetura redundante, tanto para os servidores quanto para&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[585],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.\" \/>\n<meta property=\"og:description\" content=\"1. Introdu\u00e7\u00e3o Visando a melhoria na disponibilidade do sistema e sua toler\u00e2ncia a falhas, \u00e9 comum a escolha de sistemas SCADA com arquitetura redundante, tanto para os servidores quanto para&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:42:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-28T18:06:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%20Rede.jpg\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.\",\"datePublished\":\"2019-03-25T20:42:26+00:00\",\"dateModified\":\"2024-03-28T18:06:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\"},\"wordCount\":883,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"Domain \/ E3Server \/ HotStandBy\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\",\"url\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\",\"name\":\"[:pt]Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:42:26+00:00\",\"dateModified\":\"2024-03-28T18:06:41+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.[:] - Elipse Knowledgebase","og_description":"1. Introdu\u00e7\u00e3o Visando a melhoria na disponibilidade do sistema e sua toler\u00e2ncia a falhas, \u00e9 comum a escolha de sistemas SCADA com arquitetura redundante, tanto para os servidores quanto para&hellip;","og_url":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:42:26+00:00","article_modified_time":"2024-03-28T18:06:41+00:00","og_image":[{"url":"http:\/\/kb.elipse.com.br\/pt-br\/images\/ID4727\/Figura%20Rede.jpg"}],"author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.","datePublished":"2019-03-25T20:42:26+00:00","dateModified":"2024-03-28T18:06:41+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/"},"wordCount":883,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["Domain \/ E3Server \/ HotStandBy"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/","url":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/","name":"[:pt]Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:42:26+00:00","dateModified":"2024-03-28T18:06:41+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/uso-de-hot-standby-do-elipse-e3elipse-power-em-maquinas-com-placas-de-rede-redundantes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"Uso de Hot Standby do Elipse E3\/Elipse Power em m\u00e1quinas com placas de rede redundantes."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3046"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=3046"}],"version-history":[{"count":4,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3046\/revisions"}],"predecessor-version":[{"id":16171,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/3046\/revisions\/16171"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=3046"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=3046"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=3046"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}