{"id":1253,"date":"2019-03-25T17:34:17","date_gmt":"2019-03-25T20:34:17","guid":{"rendered":"http:\/\/xexeu.elipse.com.br\/pt\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/"},"modified":"2019-03-25T17:34:17","modified_gmt":"2019-03-25T20:34:17","slug":"bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver","status":"publish","type":"post","link":"https:\/\/kb.elipse.com.br\/en\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/","title":{"rendered":"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer."},"content":{"rendered":"<div style=\"text-align: justify;\"><span style=\"font-weight: bold;\">RESUMO<\/span><\/p>\n<p>Em um script executado no <span style=\"font-weight: bold;\">Viewer<\/span>, a refer\u00eancia ao objeto <span style=\"font-weight: bold;\">AlarmServer <\/span>\u00e9 perdida ap\u00f3s a chamada do m\u00e9todo <span style=\"font-style: italic;\">Deactivate<\/span>. Isto poder\u00e1 causar erro no script, caso ele seja usado posteriormente.<\/p>\n<p><span style=\"font-weight: bold;\">COMO REPRODUZIR O PROBLEMA<\/span><\/p>\n<p>Execute o seguinte script em uma aplica\u00e7\u00e3o:<\/p>\n<p><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">DIM alarmServer <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">SET alarmServer = Application.GetObject(&#8220;AlarmServer&#8221;) <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">alarmServer.Deactivate() <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">alarmServer.Activate() &#8216; <=== erro de script!!!<\/span><\/p>\n<p>Na quarta linha ocorre o erro de script, pois n\u00e3o existe mais a refer\u00eancia para o objeto &#8220;AlarmServer&#8221;.<\/p>\n<p><span style=\"font-weight: bold;\">WORKAROUND<\/span><\/p>\n<p>Para evitar este problema, deve-se adicionar o comando <span style=\"font-style: italic;\">GetObject <\/span>do objeto <span style=\"font-weight: bold;\">Application <\/span>ap\u00f3s o m\u00e9todo <span style=\"font-style: italic;\">Deactivate <\/span>do objeto <span style=\"font-weight: bold;\">AlarmServer<\/span>. Isto faz com que a refer\u00eancia para o objeto seja novamente inserida na vari\u00e1vel <span style=\"font-weight: bold;\">AlarmServer<\/span>. A lista de comandos fica a assim:<\/p>\n<p><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">DIM alarmServer <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">SET alarmServer = Application.GetObject(&#8220;AlarmServer&#8221;) <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">alarmServer.Deactivate() <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">SET alarmServer = Application.GetObject(&#8220;AlarmServer&#8221;) <\/span><br style=\"font-family: Courier New; color: rgb(0, 0, 0);\"><span style=\"font-family: Courier New; color: rgb(0, 0, 0);\">alarmServer.Activate()<\/span><\/p>\n<p><span style=\"font-weight: bold;\">SITUA\u00c7\u00c3O<\/span><\/p>\n<p>A <span style=\"font-weight: bold;\">Elipse Software<\/span> confirmou que este \u00e9 de fato um <span style=\"font-weight: bold;\">erro <\/span>nos produtos listados no final deste artigo. O download da corre\u00e7\u00e3o est\u00e1 <a  href=\"http:\/\/www.elipse.com.br\/downloads.aspx?id_produto=1&#038;versao=3.2&#038;doc=false&#038;idioma=1%20\">aqui<\/a>. <br \/><br style=\"font-weight: bold;\"><span style=\"font-weight: bold;\">ESTE ARTIGO APLICA-SE AOS SEGUINTES PRODUTOS <\/span><br \/><br style=\"font-weight: bold;\"><span style=\"font-weight: bold;\">Elipse E3<\/span> vers\u00e3o 2.0 ou inferior<br \/><span style=\"font-weight: bold;\">Elipse E3 <\/span>vers\u00e3o 2.5<br \/><span style=\"font-weight: bold;\">Elipse E3<\/span> vers\u00e3o 3.0<br \/><span style=\"font-weight: bold;\">Elipse E3<\/span> vers\u00e3o 3.1<\/div>\n","protected":false},"excerpt":{"rendered":"<p>RESUMO Em um script executado no Viewer, a refer\u00eancia ao objeto AlarmServer \u00e9 perdida ap\u00f3s a chamada do m\u00e9todo Deactivate. Isto poder\u00e1 causar erro no script, caso ele seja usado&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0},"categories":[580],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer. - Elipse Knowledgebase<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.\" \/>\n<meta property=\"og:description\" content=\"RESUMO Em um script executado no Viewer, a refer\u00eancia ao objeto AlarmServer \u00e9 perdida ap\u00f3s a chamada do m\u00e9todo Deactivate. Isto poder\u00e1 causar erro no script, caso ele seja usado&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\" \/>\n<meta property=\"og:site_name\" content=\"Elipse Knowledgebase\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/elipsesoftware\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-25T20:34:17+00:00\" \/>\n<meta name=\"author\" content=\"Elipse Software\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elipse Software\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\"},\"author\":{\"name\":\"Elipse Software\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\"},\"headline\":\"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.\",\"datePublished\":\"2019-03-25T20:34:17+00:00\",\"dateModified\":\"2019-03-25T20:34:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\"},\"wordCount\":206,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"articleSection\":[\"AlarmServer \/ AlarmConfig\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\",\"url\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\",\"name\":\"[:pt]BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.[:] - Elipse Knowledgebase\",\"isPartOf\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#website\"},\"datePublished\":\"2019-03-25T20:34:17+00:00\",\"dateModified\":\"2019-03-25T20:34:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/kb.elipse.com.br\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/kb.elipse.com.br\/#website\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"name\":\"Elipse Knowledgebase\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/kb.elipse.com.br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/kb.elipse.com.br\/#organization\",\"name\":\"Elipse Software\",\"url\":\"https:\/\/kb.elipse.com.br\/\",\"sameAs\":[\"http:\/\/www.facebook.com\/elipsesoftware\"],\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"contentUrl\":\"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png\",\"width\":161,\"height\":58,\"caption\":\"Elipse Software\"},\"image\":{\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87\",\"name\":\"Elipse Software\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g\",\"caption\":\"Elipse Software\"},\"url\":\"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer. - Elipse Knowledgebase","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/","og_locale":"en_US","og_type":"article","og_title":"[:pt]BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.[:] - Elipse Knowledgebase","og_description":"RESUMO Em um script executado no Viewer, a refer\u00eancia ao objeto AlarmServer \u00e9 perdida ap\u00f3s a chamada do m\u00e9todo Deactivate. Isto poder\u00e1 causar erro no script, caso ele seja usado&hellip;","og_url":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/","og_site_name":"Elipse Knowledgebase","article_publisher":"http:\/\/www.facebook.com\/elipsesoftware","article_published_time":"2019-03-25T20:34:17+00:00","author":"Elipse Software","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elipse Software","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#article","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/"},"author":{"name":"Elipse Software","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87"},"headline":"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.","datePublished":"2019-03-25T20:34:17+00:00","dateModified":"2019-03-25T20:34:17+00:00","mainEntityOfPage":{"@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/"},"wordCount":206,"commentCount":0,"publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"articleSection":["AlarmServer \/ AlarmConfig"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/","url":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/","name":"[:pt]BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer.[:] - Elipse Knowledgebase","isPartOf":{"@id":"https:\/\/kb.elipse.com.br\/#website"},"datePublished":"2019-03-25T20:34:17+00:00","dateModified":"2019-03-25T20:34:17+00:00","breadcrumb":{"@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/kb.elipse.com.br\/bug0010183-erro-em-script-do-viewer-apos-chamar-o-metodo-deactivate-do-objeto-alarmserver\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/kb.elipse.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"BUG-0010183: Erro em script do Viewer ap\u00f3s chamar o m\u00e9todo Deactivate do objeto AlarmServer."}]},{"@type":"WebSite","@id":"https:\/\/kb.elipse.com.br\/#website","url":"https:\/\/kb.elipse.com.br\/","name":"Elipse Knowledgebase","description":"","publisher":{"@id":"https:\/\/kb.elipse.com.br\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/kb.elipse.com.br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/kb.elipse.com.br\/#organization","name":"Elipse Software","url":"https:\/\/kb.elipse.com.br\/","sameAs":["http:\/\/www.facebook.com\/elipsesoftware"],"logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/","url":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","contentUrl":"https:\/\/kb.elipse.com.br\/wp-content\/uploads\/2019\/05\/schererelipse-com-br\/logoElipse.png","width":161,"height":58,"caption":"Elipse Software"},"image":{"@id":"https:\/\/kb.elipse.com.br\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/def69ea453ea60b250497b89225a9f87","name":"Elipse Software","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/kb.elipse.com.br\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ff1f7ec38f4687b06f6851d97b3cd2d0?s=96&d=mm&r=g","caption":"Elipse Software"},"url":"https:\/\/kb.elipse.com.br\/en\/author\/webmasterelipse-com-br\/"}]}},"_links":{"self":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/1253"}],"collection":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/comments?post=1253"}],"version-history":[{"count":0,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/posts\/1253\/revisions"}],"wp:attachment":[{"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/media?parent=1253"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/categories?post=1253"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/kb.elipse.com.br\/en\/wp-json\/wp\/v2\/tags?post=1253"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}