KB-29686: Viewing Driver’s status.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-29686: Viewing Driver’s status.

Question: How can I view the Driver’s status? Solution: To do so, you must create a tag and configure its parameters as N1=-1, N2=0, N3=0 and N4=2, or import a…

Leia Mais

KB-28571: SCADA full screen closed with Ctrl+F4.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-28571: SCADA full screen closed with Ctrl+F4.

Question: Why is a SCADA full screen being closed when pressing Ctrl+F4? Solution: This is SCADA’s standard behavior. To change it, you can use the Ctrl+F4 combination in an OnKeyPress()…

Leia Mais

KB-28355: Recovering corrupted application.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-28355: Recovering corrupted application.

Question: How can I recover an application from the .BAK file after the .APP file had been corrupted? Solution: To do so, follow these procedures: Delete the corrupted .APP file.…

Leia Mais

KB-26683: Driver file’s path in Windows CE.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-26683: Driver file’s path in Windows CE.

Question: Since Windows CE does not have a C: folder, where should the I/O driver be placed when Elipse SCADA is using this platform?Solution: When working in an application for…

Leia Mais

KB-27237: Executing two SCADA applications in the same computer.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-27237: Executing two SCADA applications in the same computer.

Question:Can two Elipse SCADA applications be executed in the same computer at the same time? Solution: No, two SCADA applications cannot be executed in the same computer simultaneously. Possible alternatives…

Leia Mais

KB-24049: Importing a screen from another Elipse SCADA application.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-24049: Importing a screen from another Elipse SCADA application.

Question: Can a screen from another Elipse SCADA application be imported? Solution: Yes. To do so, in the new application, click Import… button on the Organizer’s Application item, and select…

Leia Mais

KB-23147: Refreshing Elipse SCADA’s date and time when editing it on the computer.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-23147: Refreshing Elipse SCADA’s date and time when editing it on the computer.

Question: How can I set up Elipse SCADA’s date and time to be refreshed whenever the computer’s date/time changes? Solution: To do so, you must create the following key in…

Leia Mais

KB-34518: Expand Bits option.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-34518: Expand Bits option.

Question: What is Expand Bits option for? Solution: Some PLCs do not allow direct access to bit variables, such as in an input or output. In such cases, you must…

Leia Mais

KB-33332: Trigonometric functions in Elipse SCADA.

25 de março de 20199 de setembro de 2019Elipse SoftwareDeixe um comentário on KB-33332: Trigonometric functions in Elipse SCADA.

Question: Can I perform trigonometric functions with SCADA? Solution: Yes, they can be performed with functions such as Cos, Sin, and Tan, among others, in the Global Manager.

Leia Mais